VesselSeed

Bearing lab

Can phase distinguish a fault from a change in speed?

A damaged bearing can send a pulse each time a roller crosses a defect. Speed changes how often those pulses arrive. Explore that effect here, then see how phase alignment performed on a real test rig.

Synthetic vibration

0 ms125 ms250 ms

The simulator uses a seeded noise signal and a damped pulse at 7.76 crossings per shaft revolution. Turn the impulse to zero to see shaft vibration and noise alone. The controls affect only the illustration.

Measured on real bearings

Phase gave no reduction in false alarms when switched on.

All three methods detected 44 of 48 damaged recordings at matched sensitivity (91.7%). Shorter bars mean fewer healthy recordings flagged.

Speed-adjusted envelope baseline 47 / 48
Baseline with RIC phase feature 46 / 48
Same fitted model, phase switched off 46 / 48

On this rig, at this detection rate, every method flagged almost every healthy recording. The one-record difference from the standalone baseline persisted with phase switched off.

What was measured?

96 recordings from three physical NU206 bearings, before and after artificial inner-ring damage. Each method received the same first two seconds of three-axis acceleration sampled at 20 kHz and the recorded shaft RPM. The subset used four speed settings, the lowest and highest load settings, one mounting position and two runs. A physical bearing contributed repeated observations.

For each test recording, model fitting excluded its entire bearing and its target speed. The baseline measures envelope power around the first three harmonics of the expected inner-race frequency. A second fitted model adds the published multi-harmonic RIC phase-alignment score (equations 4 and 5), applied to phase estimates across eight intervals. The ablation sets that feature to its training mean with the fitted weights held fixed.

The matched-sensitivity comparison selected thresholds retrospectively using out-of-fold scores. In a separate check with thresholds set using training data alone, the baseline detected 36/48 with 36 false alarms, phase on detected 36/48 with 34 false alarms, and phase off detected 27/48 with 36 false alarms. The matched experiment tests one implementation of a published component. Industrial performance and a full RIC pipeline remain untested.

Download per-recording scores · Reproduce the comparison